Commercial Elastomeric Coatings in St. Rose, LA
Big Easy Roofing specifies elastomeric coatings across St. Rose and the east bank of St. Charles Parish. The building code names a material standard for acrylic, silicone and moisture-cured polyurethane coatings, and, in our reading, the roof that is already there, with the manufacturer’s requirements, narrows which chemistry is worth shortlisting.
St. Rose commercial elastomeric coatings at a glance
Where an elastomeric coating goes over an existing roof, it is a flexible film that has to bond to what is there. The building code lists material standards for seven named coating materials in one table, and three of its seven rows are acrylic, silicone and moisture-cured polyurethane. The roof is the first filter.
One table of standards
In the 2021 edition of the International Building Code, as Louisiana adopts it (without Chapters 1 and 27, and subject to the commission’s listed amendments), Section 1509.2 says roof coating materials shall comply with the standards in Table 1509.2. The table has seven rows, and each pairs a coating material with an ASTM standard. Section 1509.1 also ties a coating installation to Section 1505.
Three rows we are asked about
The table pairs acrylic coating with ASTM D6083, silicone coating with ASTM D6694 and moisture-cured polyurethane coating with ASTM D6947.
The polyurethane row
The row reads “Moisture-cured polyurethane coating”. The table has no row for other polyurethane types, so for a different type our practice is to ask the manufacturer for its documentation and to put the code question to the parish.
The other four rows
The remaining rows are asphaltic emulsion coating (ASTM D1227), asphalt coating (ASTM D2823), asphalt roof coating (ASTM D4479) and aluminum-pigmented asphalt coating (ASTM D2824).
The table does not choose
Our reading, not the code’s: the table says which standard a coating material must meet. The table lists roof coating materials and does not use the word elastomeric, and we found nothing in it that says which chemistry suits which roof. The roof that is already there, its condition and the manufacturer’s requirements all bear on that.
What we will not interpret
Louisiana R.S. 37:2159.1 bars a roofing contractor from acting as a public adjuster or interpreting insurance policy coverage. We write the scope of the roof work.
This page addresses commercial roofing. Which code applies to a given building is for the parish to say, and that is especially so for a mixed use building.
Our practice is to ask the manufacturer for the product data sheet and to name the Table 1509.2 standard the product is documented to meet in the written scope. Among the factors we price elastomeric coatings on are the roof’s area, its substrate, the chemistry and the thickness specified, so call Big Easy Roofing for a scoped price on your St. Rose building.
The three chemistries against the failure modes
Once the roof has narrowed the shortlist, three failure modes we screen for rank what is left: ponding water, sun and dirt pickup, and foot traffic. The table pairs each chemistry with its code table standard. The failure mode comparison is our reading of how each behaves.
| Chemistry | Standard in Table 1509.2 | Ponding water | Sun, dirt pickup and foot traffic |
|---|---|---|---|
| Silicone | ASTM D6694 | Generally tolerates standing water once cured, and the manufacturer's product documents say what applies. | Reflectance can fall as dirt picks up on the film, and on some products the surface can be slippery when wet, so traffic lanes are specified separately. |
| Acrylic | ASTM D6083 | Many acrylic coatings are water dispersed, and in our experience some films can soften under standing water, so the manufacturer's product documents say what applies. | In our experience it wears faster than polyurethane on a traffic path, and the manufacturer's product documents say what applies. |
| Moisture-cured polyurethane | ASTM D6947 | Varies by product, and the manufacturer's product documents say. | Commonly specified where abrasion resistance leads. Some aromatic polyurethane products need a UV stable top coat, and the manufacturer's product documents say. |
The standard column is the code table’s. The performance columns are our reading of how each chemistry behaves, and the manufacturer’s product documents say what applies to a given product. Traffic lanes on a silicone or acrylic roof are often specified as the manufacturer’s walkway system, and re-coat compatibility follows in its own section.
Re-coat compatibility, and why the first chemistry matters
When a coating reaches the end of its film life, the next coat has to bond to what is left of the first. Re-coat compatibility depends on the coating already on the roof, the coating going on and the manufacturer’s requirements, and our practice is to get the incoming manufacturer’s approval and run an adhesion test on the roof first.
Silicone
In our experience the low surface energy of silicone helps it shed water and also makes it difficult to prime over. Silicone over silicone with the correct preparation is usually the re-coat path, subject to the manufacturer, and our practice is to require the incoming manufacturer’s approval and an adhesion test before any other chemistry goes over silicone.
Acrylic
In our experience a sound acrylic film often accepts another acrylic and, with the incoming manufacturer’s written approval and an adhesion test, some other chemistries after cleaning and any primer the product calls for. The trade off is on the ponding and traffic columns.
Polyurethane
Polyurethane re-coats, moisture-cured or otherwise, depend on the product, the primer and, for some aromatic types, a UV stable top coat within the window the manufacturer sets.
The code table
Table 1509.2 names a standard for each material. We found nothing in it about how one coating bonds to another, so compatibility is confirmed with the manufacturer in writing.
Where the first choice comes back
Our reading: a silicone roof at the end of its film life has several paths. Silicone over silicone with the correct cleaning is the usual one. Another chemistry over silicone is possible with the incoming manufacturer’s written approval and an adhesion test. Removal to bare substrate is another.
So choosing silicone today usually narrows the re-coat choices. On a roof that ponds that is often a reasonable trade, and we say so at the specification stage.
How the survey ranks the failure modes
Our practice is to ask every roof three screening questions, which are not an exhaustive list: where water stands after rain, how much foot traffic the roof carries, and how the surface looks after sun and dirt. Our practice is to record the answers on the survey and to rank the failure modes from them.
The ranking helps choose between the chemistries the substrate leaves on the shortlist, alongside the manufacturer’s requirements, and it goes into the written scope.
How the standard goes into the scope
Our practice is to name the chemistry, the standard it is documented to meet and the thickness in the written scope, so quotes can be compared line by line. The code table gives the standard, the manufacturer’s product documents or system specification give the thickness and the preparation, product by product, and the survey gives the condition of the roof.
Name the standard
Our practice: the scope names the product, the Table 1509.2 standard it is documented to meet and the manufacturer’s product document it comes from.
Where a product document names a different standard or none, we ask the manufacturer before the product is specified.
State the thickness
Our practice: the scope states the dry film thickness the manufacturer specifies for the roof, and wet film readings are taken as the coating goes on.
A coating applied thinner than the manufacturer specifies may not give the performance the product was designed for, so the thickness is a line in the scope and not an assumption.
Preparation and primer
Our practice: the scope lists the cleaning and any primer the product calls for, because adhesion depends on the surface the coating goes on.
Whether a coating scope needs a permit or an inspection is a question we put to the parish before the scope is priced.
Big Easy Roofing Process
Four steps. The survey ranks the failure modes before a chemistry is specified.

01 Survey the substrate
What the existing roof is, its condition, seams, penetrations, drainage and, where the scope calls for it, a test for wet insulation.
02 Rank the failure modes
Ponding water, sun and dirt pickup, and foot traffic, ranked from what the survey records.
03 Specify the system
The chemistry, the Table 1509.2 standard it is documented to meet, the thickness and the preparation, with the parish answer recorded where we have one.
04 Apply, measure, hand over
Application to the manufacturer’s instructions and within its weather limits, wet film readings as it goes on, and the scope handed over with the manufacturer’s warranty documents where one is issued.
Everything else we do in St. Rose
The rest of the Big Easy Roofing services available in St. Rose, each with its own page. The code sections for a coating, and what the regional roofing handout does not mention, are on the commercial roof coating page. The moisture survey behind any coating check is on the commercial inspection page.

Roof Replacement in St. Rose
Read More
Roof Repairs in St. Rose
Read More
Roof Inspection in St. Rose
Read More
Hail Damage Roof Repair in St. Rose
Read More
Storm Damage Roof Repair in St. Rose
Read More
Storm Damage Emergency Response in St. Rose
Read More
Emergency Roofing in St. Rose
Read More
Roof Leak Detection in St. Rose
Read More
Roof Maintenance in St. Rose
Read More
Roof Coating in St. Rose
Read More
Roof Ventilation in St. Rose
Read More
Roof Weatherproofing in St. Rose
Read More
Roof Restoration in St. Rose
Read More
Roof Flashing Repair in St. Rose
Read More
Fascia Board Installation and Repair in St. Rose
Read More
Gutters and Downspouts Installation in St. Rose
Read More
Gutters and Downspouts Repair in St. Rose
Read More
Siding Installation in St. Rose
Read More
Asbestos Roof Removal in St. Rose
Read More
Roof Damage Documentation in St. Rose
Read More
Commercial Roof Replacement in St. Rose
Read More
Commercial Roof Repairs in St. Rose
Read More
Commercial Roof Inspections in St. Rose
Read More
Commercial Hail Damage Repair in St. Rose
Read More
Commercial Re-Roofing in St. Rose
Read More
Commercial Roof Coating in St. Rose
Read More
Commercial Roof Ventilation in St. Rose
Read More
Commercial Roof Leak Detection in St. Rose
Read More
Commercial Siding Installation in St. Rose
Read MoreSt. Rose Commercial Elastomeric Coatings FAQs
The code table for coating materials, how the chemistries compare, and what to settle before the scope is priced.
Topic
Question not here?
Ask us anything about coating your St. Rose roof. No charge and no obligation.
Call (504) 800-8196Does the building code set a standard for roof coatings?
In the 2021 edition of the International Building Code, as adopted by Louisiana, Section 1509.2 says roof coating materials shall comply with the standards in Table 1509.2. The table has seven rows, and each pairs a coating material with an ASTM standard.
Which standards apply to acrylic, silicone and moisture-cured polyurethane?
The table pairs acrylic coating with ASTM D6083, silicone coating with ASTM D6694 and moisture-cured polyurethane coating with ASTM D6947. It has no row for other polyurethane types.
Does the code say which chemistry to use?
Our reading: Section 1509.2 and Table 1509.2 name standards and do not rank chemistries. The roof that is already there, its leading failure mode and the manufacturer’s requirements bear on the choice.
Which chemistry suits a roof that ponds?
In our reading silicone is normally on the shortlist, because it generally tolerates standing water once cured. Some acrylic films can soften under standing water.
Can I change chemistry at the next re-coat?
Sometimes. In our experience silicone over silicone is the usual path, and our practice is to require the incoming manufacturer’s approval and an adhesion test before any other chemistry goes over silicone. Other re-coats depend on the product, the primer and the manufacturer.
Does an elastomeric coating need a permit in St. Rose?
We found no mention of a roof coating in the commercial permitting guide or the regional roofing handout we read, so we do not tell you a coating does or does not need a permit. St. Charles Parish Planning and Zoning on (985) 783-5060 is the first call for a specific scope, the commercial permitting guide directs building code questions to a South Central Development plan reviewer, and we ask before the scope is priced.
Can an elastomeric coating fix a failing roof?
For a re-coating scope a coating is a film over the existing roof, so the survey and the manufacturer’s requirements decide whether it fits. Our practice is to treat wet insulation, open seams or a delaminated covering as calling for a repair or replacement scope first.
Can my roofer act as my public adjuster?
Louisiana R.S. 37:2159.1 bars a roofing contractor from acting as a public adjuster or interpreting insurance policy coverage. Ask your insurer about coverage.
What does an elastomeric coating cost?
It is priced on the area, the substrate, the chemistry and the thickness specified, after the roof is surveyed. Call for a scoped price.
Match the chemistry to the roof before any coating is priced
We survey the substrate, rank the failure modes, and name the chemistry and its code table standard in a written scope. If you would rather start in writing, tell us what the job involves and we will come back with an estimate.
Call (504) 800-8196